Milestone Pump Co., Ltd ONLY PUMP, MORE THAN PUMP
banner
Home » Products > Water Pumps > Split Casing Water Pump
Product Categories
High Flow Split Case Water Pump

High Flow Split Case Water Pump

Flood drianage double suction water pump is a single-stage double-suction horizontal split centrifugal pump. It is used to transport pure water and the liquid which physical and chemical nature is similar with water, the maximum temperature isn't more than 80 , this series of pump is suitable for water supply and drainage in factories, mines and cities, power station, drainage and irrigation of farming, and kinds of hydraulic projects.

Send InquiryChat Now

High flow split case water pump

Feature

High efficiency and energy saving: the pump has a high efficiency, a wide range of flow has a high operating efficiency, can reduce operating costs and select a smaller power motor, is Zui energy-saving high efficiency pump.
Excellent anti cavitation performance: the pump has excellent anti cavitation performance through special design, which can save capital construction cost compared with the traditional double suction pump.
Noise reduction and vibration reduction: the pump adopts the careful design of reducing noise and vibration, extending the service life of the equipment, making it more economical and environmentally friendly.
A variety of material combinations: a variety of material combinations make the SN pump suitable for a wider range of fields, according to different requirements, choose different material combinations.

Flood Drainage Double Suction Water Pump.jpg

Installation of axially split pump            


1. Check whether the S-type axially split pump and motor are damaged.
2. The installation height of the water pump, plus the hydraulic loss of the suction pipeline and its speed energy, shall not be greater than the allowable suction vacuum height value specified in the sample. The foundation size shall conform to the installation size of the pump unit
3. Installation sequence:
① Place the water pump on the concrete foundation embedded with foundation bolts, use the method of adjusting the wedge-shaped cushion block between them to calibrate the level, and properly tighten the foundation bolts to prevent walking.
② Pour concrete between foundation and pump foundation.
③ After the concrete is dry and fixed, tighten the anchor bolts and recheck the levelness of S-type split pump.
④ Correct the concentricity of the motor shaft and the pump shaft. Make the two shafts in a straight line. The concentricity tolerance on the two shafts is 0.1mm, and the end clearance along the circumference is 0.3mm
After connecting the inlet and outlet water pipes and commissioning, calibrate them once respectively, which shall still meet the above requirements).
⑤ After checking that the rotation direction of the motor is the same as that of the water pump, install the coupling and the coupling pin.
4. The inlet and outlet water pipes shall be supported by another bracket instead of the pump body.
5. The joint surface between the water pump and the pipeline shall ensure good air tightness, especially the water inlet pipeline, which shall be strictly guaranteed not to leak, and there shall be no possibility of air entrapment on the device.
6. For example, when the S-type axially split pump is installed above the water inlet level, in order to start the pump, the bottom valve can be installed generally. Vacuum water diversion can also be used.
7. Generally, gate valve and check valve shall be installed between the water pump and the outlet pipeline (if the lift is less than 20 m, it can not be used), and the check valve shall be installed behind the gate valve.
The installation method mentioned above refers to the pump unit without a common base.
Install the pump with a common base, and adjust the wedge-shaped sizing block between the base and the concrete foundation to correct the level of the unit. Then pour concrete in between. The installation principle and requirements are the same as those of the unit without common base.

XS100-375A

Packing

Flood Drainage Double Suction Water Pump.jpg

Contact us

Tammy
008615175232736

tammy@mstpump.cn

Products specification

MS Clear Water Performance

Type

Capacity

Head

Speed

Shaft power

m³/h

m

r/min

kw


150MS-78

160

78

2900

45

150MS-50

160

50

2900

27.3

200MS-95

280

95

2900

94

200MS-63

280

63

2900

59.3

200MS-42

280

42

2900

37.7

250MS-65

485

65

1450

108.7

250MS-39

485

39

1450

62.1

250MS-24

485

24

1450

36.9

250MS-14

485

14

1450

21.7

300MS-90

790

90

1450

249.8

300MS-58

790

58

1450

148.5

300MS-32

790

32

1450

79

300MS-19

790

19

1450

46.9

300MS-12

790

12

1450

31.1

350MS-125

1260

125

1450

531

350MS-75

1260

75

1450

304

350MS-44

1260

44

1450

177.6

350MS-26

1260

26

1450

101.5

350MS-16

1260

16

1450

63.8

500MS-13

2020

13

980

86.2

500MS-35

2020

35

980

219

500MS-98

2020

98

980

678

600MS-22

3241

22

980

231.8

600MS-75

3060

75

980

694.4

800MS-32

5500

32

730

538.5

800MS-47

5500

47

730

782.2


Product Performance curve

Flood Drainage Double Suction Water Pump.jpg


Hot Tags: high flow split case water pump, China, manufacturers, suppliers, distributor, wholesale, price, buy, for sale

Inquiry